After I install PolSARPro 6.0 and tried to launch up sentinel 1 A/B mission, I got some error about "widget(PSPEDUC1) missing “ or alik...
After I install PolSARPro 6.0 and tried to launch up sentinel 1 A/B mission, I
got some error about "widget(PSPEDUC1) missing “ or alike warnings and failed
start up this module.
It took me some time to figure out this is due
to a misspelling in the main TCL file “PolSARpro_v6.0.2_Biomass_Edition.tcl”
.
can't read "widget(PSPEDUC1)": no such element in array
can't read "widget(PSPEDUC1)": no such element in array
while executing
"$widget(PSPEDUC1) configure -state disable"
invoked from within
".top3.fra66.cpd69.but93 invoke"
("uplevel" body line 1)
invoked from within
"uplevel #0 [list $w invoke]"
(procedure "tk::ButtonUp" line 24)
invoked from within
"tk::ButtonUp .top3.fra66.cpd69.but93"
(command bound to event)
at line 48859,
"$widget(PSPEDUC1) configure -state disable "
and line 48931
"$widget(PSPEDUC1) configure -state normal ",
“PSPEDUC1” in the brackets
has to be changed to “PSPEDUC”, then it will work.
In This video we
make a change in the TCL file of PolSARpro and remove 1 after PSPEDUC
GiS English 2021